Indoor and Built Environment

 

Advanced Search

Journal Navigation

Journal Home

Subscriptions

Archive

Contact Us

Table of Contents

Register here to gain access to SAGE's 500+ Journals Online

Sign In to gain access to subscriptions and/or personal tools.
This Article
Right arrow Full Text (PDF)
Right arrow References
Right arrow Alert me when this article is cited
Right arrow Alert me if a correction is posted
Services
Right arrow Email this article to a friend
Right arrow Similar articles in this journal
Right arrow Alert me to new issues of the journal
Right arrow Add to Saved Citations
Right arrow Download to citation manager
Right arrowRequest Permissions
Right arrow Request Reprints
Right arrow Add to My Marked Citations
Citing Articles
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by Rydock, J.P.
Right arrow Articles by Brunsell, J.T.
Right arrow Search for Related Content
Social Bookmarking
 Add to CiteULike   Add to Connotea   Add to Del.icio.us   Add to Digg   Add to Reddit   Add to Technorati  
What's this?
Indoor and Built Environment, Vol. 11, No. 1, 38-43 (2002)
DOI: 10.1177/1420326X0201100105

Effectiveness of Radon Mitigation Measures in 12 Houses 10 Years after Implementation

J.P. Rydock

Norwegian Building Research Institute, Oslo, Norway

A. Næss-Rolstad

Norwegian Building Research Institute, Oslo, Norway

J.T. Brunsell

Norwegian Building Research Institute, Oslo, Norway

Results are presented of radon concentrations in 12 houses 10 years after radon mitigation measures were implemented to reduce elevated radon concentrations in the houses. The houses were part of an earlier radon research project in which the home-owners received remediation advice from radon researchers, and a single contractor carried out the reduction measures. Remedia tion in nine of the houses was principally by installing an internal sump, in another by installing an external sump, in one by ventilating the crawl-space under the house, and one house had had a naturally ventilated sump sys tem built into the house and later had a fan installed to increase the sub-slab depressurization. The measure ments showed that ten years after radon reduction mea sures were implemented, only 3 of 12 houses had radon concentrations under the present-day action level of 200 Bq·m-3 (5.4 pCi.1-1) in Norway. The results suggest that radon levels should be measured at periodic inter vals after remediation, perhaps once every five years, to ensure that concentrations continue to be at acceptable levels.

Key Words: Indoor air • Radon. Sump • Ventilation