Advanced Search

Journal Navigation

Journal Home

Subscriptions

Archive

Contact Us

Table of Contents

Sign In to gain access to subscriptions and/or personal tools.
Indoor and Built Environment
This Article
Right arrow Full Text (PDF)
Right arrow References
Right arrow Alert me when this article is cited
Right arrow Alert me if a correction is posted
Services
Right arrow Email this article to a friend
Right arrow Similar articles in this journal
Right arrow Alert me to new issues of the journal
Right arrow Add to Saved Citations
Right arrow Download to citation manager
Right arrowRequest Permissions
Right arrow Request Reprints
Right arrow Add to My Marked Citations
Citing Articles
Right arrow Citing Articles via Google Scholar
Right arrow Citing Articles via Scopus
Google Scholar
Right arrow Articles by Sonkawade, R.G.
Right arrow Articles by Ramola, R.C.
Right arrow Search for Related Content
Social Bookmarking
 Add to CiteULike   Add to Complore   Add to Connotea   Add to Del.icio.us   Add to Digg   Add to Reddit   Add to Technorati   Add to Twitter  
What's this?

Radon Studies in the Vertical 15 UD Pelletron Accelerator Facility

R.G. Sonkawade

Nuclear Science Centre, New Delhi

S.P. Lochab

Nuclear Science Centre, New Delhi

R.C. Ramola

Department of Physics, HNB Garhwal University, Badshahi Thaul Campus, Tehri Garhwal, India

Radon has been observed in the air of the 15 UD Pelle tron facility under different meteorological conditions, varying through the height of the Pelletron tower and in areas with and without air conditioning. The radon con centration in air-conditioned rooms in the inner part of the tower has been observed to be slightly greater than in the non-air-conditioned rooms towards the outside. The concentration of radon varied with height and mete orological parameters as well as with the time of day. Radon levels reached a maximum in the early morning hours and a minimum in the afternoon. Radon concen trations were found to change with changing seasonal conditions. The ratio of maximum to minimum values for indoor radon concentrations was found to vary in the range of 2-5 in all the three seasons, but the winter-to- rainy season ratio was slightly greater than that for sum mer. The Pelletron tower was suitable for a study of changes in radon levels with respect to height. Variation of radon concentration with climatic changes, hourly variations, and variation at different levels in the inner and outer parts of the tower were measured.

Key Words: Indoor radon • Temperature • Pressure • Relative humidity

Indoor and Built Environment, Vol. 11, No. 4, 221-226 (2002)
DOI: 10.1177/1420326X0201100407