Advanced Search

Journal Navigation

Journal Home

Subscriptions

Archive

Contact Us

Table of Contents

Sign In to gain access to subscriptions and/or personal tools.
Indoor and Built Environment
This Article
Right arrow Full Text (PDF)
Right arrow References
Right arrow Alert me when this article is cited
Right arrow Alert me if a correction is posted
Services
Right arrow Email this article to a friend
Right arrow Similar articles in this journal
Right arrow Alert me to new issues of the journal
Right arrow Add to Saved Citations
Right arrow Download to citation manager
Right arrowRequest Permissions
Right arrow Request Reprints
Right arrow Add to My Marked Citations
Citing Articles
Right arrow Citing Articles via Google Scholar
Right arrow Citing Articles via Scopus
Google Scholar
Right arrow Articles by Wan, M.P.
Right arrow Articles by Chao, C. Y.
Right arrow Search for Related Content
Social Bookmarking
 Add to CiteULike   Add to Complore   Add to Connotea   Add to Del.icio.us   Add to Digg   Add to Reddit   Add to Technorati   Add to Twitter  
What's this?

Experimental Study of Thermal Comfort in an Office Environment with an Underfloor Ventilation System

M.P. Wan

Department of Mechanical Engineering, Hong Kong University of Science and Technology, Kowloon, Hong Kong

Christopher Y. Chao

Department of Mechanical Engineering, Hong Kong University of Science and Technology, Kowloon, Hong Kong

Frequent changes in arrangement in office space and the huge amount of cables brought about by the extensive use of computers make the implementation of raised flooring a necessity in modern office buildings. Under floor ventilation systems that make use of the underfloor plenum for conditioned air distribution will therefore increase in popularity as they extend the flexibility of building services and take advantage of the raised floor to accommodate the HVAC system. Previous research has revealed that the top return type underfloor system saves a significant amount of energy, as the supply air temperature can be higher than that in a ceiling-based system. However, thermal discomfort due to tempera ture non-uniformity was also reported. This paper presents the experiment results of a laboratory study of the thermal performance for a floor return (FR) type underfloor system under different heat load densities and supply air temperatures. Vertical temperature differ ences and air velocities were found to be within the com fort limits stated in major international standards. The measured predicted mean vote and predicted percent age of dissatisfied values also satisfied the ISO Standard 7730. A comfortable environment was maintained by the FR type system under a dense internal heat load and with the supply air temperature set at as high as 18°C.

Key Words: Thermal comfort • Underfloor ventilation • Predicted mean vote • Predicted percentage of dissatisfied • Air temperature • Air velocity

Indoor and Built Environment, Vol. 11, No. 5, 250-265 (2002)
DOI: 10.1177/1420326X0201100502