Advanced Search

Journal Navigation

Journal Home

Subscriptions

Archive

Contact Us

Table of Contents

Sign In to gain access to subscriptions and/or personal tools.
Indoor and Built Environment
This Article
Right arrow Full Text (PDF)
Right arrow References
Right arrow Alert me when this article is cited
Right arrow Alert me if a correction is posted
Services
Right arrow Email this article to a friend
Right arrow Similar articles in this journal
Right arrow Alert me to new issues of the journal
Right arrow Add to Saved Citations
Right arrow Download to citation manager
Right arrowRequest Permissions
Right arrow Request Reprints
Right arrow Add to My Marked Citations
Citing Articles
Right arrow Citing Articles via Google Scholar
Right arrow Citing Articles via Scopus
Google Scholar
Right arrow Articles by Kolokotroni, M.
Right arrow Articles by Katsoulas, D.
Right arrow Search for Related Content
Social Bookmarking
 Add to CiteULike   Add to Complore   Add to Connotea   Add to Del.icio.us   Add to Digg   Add to Reddit   Add to Technorati   Add to Twitter  
What's this?

Monitoring and Modelling Indoor Air Quality and Ventilation in Classrooms within a Purpose-Designed Naturally Ventilated School

M. Kolokotroni

Mechanical Engineering Department, Brunel University, Uxbridge, UK

Y.T. Ge

Mechanical Engineering Department, Brunel University, Uxbridge, UK

D. Katsoulas

Mechanical Engineering Department, Brunel University, Uxbridge, UK

This paper investigates the performance in use of ther mal passive ventilation stacks in the classrooms of a school during the summer period. Measurements of air temperature, carbon dioxide (CO2) and air velocity were carried out from which ventilation rates in the class rooms and stacks were calculated. It was found that the airflow through the passive stacks was a significant pro portion of the classroom air exchange rate and metabolic CO2 was lower in classrooms with passive stacks. The predictions of a multi-zone airflow computer model were compared with measured values. Multi-zone modelling indicated that passive stacks could significantly increase ventilation in classrooms, which would otherwise be ventilated via single side ventilation through openable windows on one external wall. It was found that if the zones are accurately represented, multi-zone modelling is able to provide a good indication of the general trends of airflow rates both for the whole classroom and the flow through passive stacks.

Key Words: Natural ventilation • School ventilation • Passive stack • Multi-zone modelling

Indoor and Built Environment, Vol. 11, No. 6, 316-326 (2002)
DOI: 10.1177/1420326X0201100603


Add to CiteULike CiteULike   Add to Complore Complore   Add to Connotea Connotea   Add to Del.icio.us Del.icio.us   Add to Digg Digg   Add to Reddit Reddit   Add to Technorati Technorati   Add to Twitter Twitter    What's this?