Advanced Search

Journal Navigation

Journal Home

Subscriptions

Archive

Contact Us

Table of Contents

CiteULike is a free service for managing and discovering scholarly references - click here to get started.

Sign In to gain access to subscriptions and/or personal tools.
Indoor and Built Environment
This Article
Right arrow Full Text (PDF)
Right arrow References
Right arrow Alert me when this article is cited
Right arrow Alert me if a correction is posted
Services
Right arrow Email this article to a friend
Right arrow Similar articles in this journal
Right arrow Similar articles in Web of Science
Right arrow Alert me to new issues of the journal
Right arrow Add to Saved Citations
Right arrow Download to citation manager
Right arrowRequest Permissions
Right arrow Request Reprints
Right arrow Add to My Marked Citations
Citing Articles
Right arrow Citing Articles via Web of Science (1)
Right arrow Citing Articles via Google Scholar
Right arrow Citing Articles via Scopus
Google Scholar
Right arrow Articles by Yik, F. W. H.
Right arrow Articles by Powell, G.
Right arrow Search for Related Content
Social Bookmarking
 Add to CiteULike   Add to Complore   Add to Connotea   Add to Del.icio.us   Add to Digg   Add to Reddit   Add to Technorati   Add to Twitter  
What's this?

Review of Isolation Ward Ventilation Design and Evaluation by Simulation

Francis W. H. Yik

Department of Building Services Engineering, The Hong Kong Polytechnic University

Greg Powell

Department of Building Services Engineering, The Hong Kong Polytechnic University

The recent resurgence of tuberculosis (TB) has led to calls for improvements in isolation facilities. This paper presents the findings of a literature review and an evaluation study of current design guidelines and performance expectations for isolation room mechanical ventilation systems. The inter-zone airflows in a typical isolation ward were modelled to unveil the issues that are critical to isolation performance and to determine the practicality of the recommendations in the literature. It was found that the air leakage through partitions and door gaps would be highly undesirable. With adequate supply and exhaust flow rate differences, and practicable construction quality, differential pressures of up to 7 Pa or higher should be achievable between isolation rooms and adjacent areas.

Key Words: Isolation • Mechanical ventilation • Pressure differences • Airflow modelling • Hong Kong

Indoor and Built Environment, Vol. 12, No. 1-2, 73-79 (2003)
DOI: 10.1177/1420326X03012001012