Indoor and Built Environment

 

Advanced Search

Journal Navigation

Journal Home

Subscriptions

Archive

Contact Us

Table of Contents

Register here to gain access to SAGE's 500+ Journals Online

Sign In to gain access to subscriptions and/or personal tools.
This Article
Right arrow Full Text (PDF)
Right arrow References
Right arrow Alert me when this article is cited
Right arrow Alert me if a correction is posted
Services
Right arrow Email this article to a friend
Right arrow Similar articles in this journal
Right arrow Alert me to new issues of the journal
Right arrow Add to Saved Citations
Right arrow Download to citation manager
Right arrowRequest Permissions
Right arrow Request Reprints
Right arrow Add to My Marked Citations
Citing Articles
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by Saarela, K.
Right arrow Articles by Järnström, H.
Right arrow Search for Related Content
Social Bookmarking
 Add to CiteULike   Add to Connotea   Add to Del.icio.us   Add to Digg   Add to Reddit   Add to Technorati  
What's this?
Indoor and Built Environment, Vol. 12, No. 4, 243-247 (2003)
DOI: 10.1177/1420326X03035096


Other

Indoor Air Quality in New Residential Buildings and Behaviour of Materials in Structures

Kristina Saarela

VTT Technical Research Centre of Finland, Espoo, Finland kristina.saarela{at}vtt.fi

Helena Järnström

VTT Technical Research Centre of Finland, Espoo, Finland

A research project was initiated in order to collect numerical reference data on material emissions during the time of construction and to follow up indoor air quality in new buildings. Seven measurement sites representative of current construction practice in Finland were chosen for investigation. Material emission measurements for surfaces were made during construction using the field and laboratory cell (FLEC) technique. The emission rates for volatile organic compounds (VOCs), formaldehyde and ammonia and the relative humidity of the floor structure were measured for the floor structure build-up stages. In addition, decay behaviour of the emissions of underlying floor structures was investigated. The concentration of VOCs, formaldehyde and ammonia in indoor air and the air exchange rate were defined for the newly finished and 6 month-old buildings. The results were compared to indoor air concentration and emission rate target values defined in the Finnish "Classification of Indoor Climate 2000".

Key Words: IAQ • Material emission • VOC • Formaldehyde • Ammonia • New buildings