Advanced Search

Journal Navigation

Journal Home

Subscriptions

Archive

Contact Us

Table of Contents

CiteULike is a free service for managing and discovering scholarly references - click here to get started.

Sign In to gain access to subscriptions and/or personal tools.
Indoor and Built Environment
This Article
Right arrow Full Text (PDF)
Right arrow References
Right arrow Alert me when this article is cited
Right arrow Alert me if a correction is posted
Services
Right arrow Email this article to a friend
Right arrow Similar articles in this journal
Right arrow Alert me to new issues of the journal
Right arrow Add to Saved Citations
Right arrow Download to citation manager
Right arrowRequest Permissions
Right arrow Request Reprints
Right arrow Add to My Marked Citations
Citing Articles
Right arrow Citing Articles via Google Scholar
Right arrow Citing Articles via Scopus
Google Scholar
Right arrow Articles by Lau, J.
Right arrow Articles by Niu, J. L.
Right arrow Search for Related Content
Social Bookmarking
 Add to CiteULike   Add to Complore   Add to Connotea   Add to Del.icio.us   Add to Digg   Add to Reddit   Add to Technorati   Add to Twitter  
What's this?

Measurement and CFD Simulation of the Temperature Stratification in an Atrium Using a Floor Level Air Supply Method

Josephine Lau

Department of Building Services Engineering, The Hong Kong Polytechnic University

J. L. Niu

Department of Building Services Engineering, The Hong Kong Polytechnic University Bejlniu{at}polyu.edu.hk

A glazed atrium is a common feature in shopping centres and in the lobbies of residential and commercial buildings. This research aimed to discover the vertical temperature distribution and cooling load reduction relating to displacement ventilation in atrium spaces. The air temperatures at different levels (0.1, 0.7, 1.2, 1.7, 3, 5 and 7 m), within a 25 m high exhibition atrium, were monitored. Using the measured surface temperatures as boundary conditions, three-dimensional computational fluid dynamic (CFD) simulations were performed to examine the vertical temperature distribution. Further, by using parametric studies, the influences of occupant load, equipment load, lighting load, floor and wall surface temperatures, and supply air conditions were investigated with 12 CFD simulation cases. Based on the simulation results, load reduction factors - with three grouping methods of heat sources - were then developed. Temperature stratification was present even under the condition of a low cooling load. Load reductions were lower for occupant and equipment loads than for a lighting load. The best grouping method was to consider the heat released from the floor as an individual group of heat sources, which is an indication that secondary heat from the floor should not be neglected during the design of displacement ventilation.

Key Words: Displacement ventilation • Computational fluid dynamics • Thermal stratification • Load reduction factor • Atrium

Indoor and Built Environment, Vol. 12, No. 4, 265-280 (2003)
DOI: 10.1177/1420326X03035917