Indoor and Built Environment

 

Advanced Search

Journal Navigation

Journal Home

Subscriptions

Archive

Contact Us

Table of Contents

Click here to register and gain free access

Sign In to gain access to subscriptions and/or personal tools.
This Article
Right arrow Full Text (PDF)
Right arrow References
Right arrow Alert me when this article is cited
Right arrow Alert me if a correction is posted
Services
Right arrow Email this article to a friend
Right arrow Similar articles in this journal
Right arrow Similar articles in ISI Web of Science
Right arrow Alert me to new issues of the journal
Right arrow Add to Saved Citations
Right arrow Download to citation manager
Right arrowRequest Permissions
Right arrow Request Reprints
Right arrow Add to My Marked Citations
Citing Articles
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by Manz, H.
Right arrow Articles by Frank, T.
Right arrow Search for Related Content
Social Bookmarking
 Add to CiteULike   Add to Connotea   Add to Del.icio.us   Add to Digg   Add to Reddit   Add to Technorati  
What's this?
Indoor and Built Environment, Vol. 13, No. 3, 233-242 (2004)
DOI: 10.1177/1420326X04043733

Analysis of Thermal Comfort Near Cold Vertical Surfaces by Means of Computational Fluid Dynamics

H. Manz

Swiss Federal Laboratories for Materials Testing and Research (EMPA), Duebendorf heinrich.manz{at}empa.ch

T. Frank

Swiss Federal Laboratories for Materials Testing and Research (EMPA), Duebendorf

Cold surfaces may cause thermal discomfort due to down draught and/or infrared radiation exchange. In this paper a cold vertical surface of 3m height in a room (3 x 3 x 5m3) was investigated using computational fluid dynamics (CFD). Also calculated were a parameter that expresses thermal discomfort for the whole human body – the predicted percentage of (those people) dissatisfied – and parameters of local discomfort such as air speed and draft risk. Five cases with different heat loads (0–80Wm–2) and with/without furniture were simulated, each case with three different temperatures of the cold surface (17.5, 15, and 10°C). The mean operative temperature was approximately 20°C in all cases. It was found that with respect to thermal discomfort, draught was more critical than reduced operative temperatures or radiation asymmetry. An increase of the heat load in the room leads to higher down draught air speeds. Therefore, experiments performed in empty rooms tend to underestimate the maximum air speed that occurs in real, furnished rooms with heat loads. A set of correlations for maximum air speed within the occupied zone is proposed. Additionally, this study shows that CFD is a valuable technique to complement and broaden knowledge gained in laboratory experiments in the field of thermal comfort.

Key Words: Thermal comfort • Down draught • Cold vertical surfaces • Computational fluid dynamics • Heat load • Set of correlations


Add to CiteULike CiteULike   Add to Connotea Connotea   Add to Del.icio.us Del.icio.us   Add to Digg Digg   Add to Reddit Reddit   Add to Technorati Technorati    What's this?