Advanced Search

Journal Navigation

Journal Home

Subscriptions

Archive

Contact Us

Table of Contents

CiteULike is a free service for managing and discovering scholarly references - click here to get started.

Sign In to gain access to subscriptions and/or personal tools.
Indoor and Built Environment
This Article
Right arrow Full Text (PDF)
Right arrow References
Right arrow Alert me when this article is cited
Right arrow Alert me if a correction is posted
Services
Right arrow Email this article to a friend
Right arrow Similar articles in this journal
Right arrow Alert me to new issues of the journal
Right arrow Add to Saved Citations
Right arrow Download to citation manager
Right arrowRequest Permissions
Right arrow Request Reprints
Right arrow Add to My Marked Citations
Citing Articles
Right arrow Citing Articles via Google Scholar
Right arrow Citing Articles via Scopus
Google Scholar
Right arrow Articles by Chau, O. K. Y.
Right arrow Articles by Leung, M. K. H.
Right arrow Search for Related Content
Social Bookmarking
 Add to CiteULike   Add to Complore   Add to Connotea   Add to Del.icio.us   Add to Digg   Add to Reddit   Add to Technorati   Add to Twitter  
What's this?

CFD Analysis of the Performance of a Local Exhaust Ventilation System in a Hospital Ward

Oliver K. Y. Chau

Department of Mechanical Engineering, The University of Hong Kong, Pokfulam Road, Hong Kong

Chun-Ho Liu

Department of Building and Real Estate, The Hong Kong Polytechnic University, Hung Hom, Kowloon, Hong Kong, liuchunho{at}graduate.hku.hk

Michael K. H. Leung

Department of Mechanical Engineering, The University of Hong Kong, Pokfulam Road, Hong Kong

Healthcare workers (HCWs) are at high risk of nosocomial infection as they frequently perform medical procedures on infectious patients that may generate bioaerosols. For example, emergency endotracheal intubations for severe acute respiratory syndrome (SARS) patients. Due to the high zonal bioaerosol concentration close to infection sources (e.g. patient’s breathing zone) local exhaust ventilation (LEV) has been identified as a practical solution to reduce the bioaerosol concentration in hospital wards. In this study, computational fluid dynamic (CFD) models have been developed to simulate the transport of infectious droplets and bioaerosols in a hospital ward to aid the design and control of a LEV system. This paper reports the details of the CFD mathematical models as well as the analyses of the distribution and suspension time of droplets and bioaerosols with respect to their size, emission direction, and emission speed. It is shown that the operation of a well-designed LEV system can effectively remove infectious droplets and bioaerosols from the breathing zone of a HCW.

Key Words: Computational fluid dynamic (CFD) • Mathematical model • Local exhaust ventilation (LEV) • Bioaerosols • Nosocomial infection

Indoor and Built Environment, Vol. 15, No. 3, 257-271 (2006)
DOI: 10.1177/1420326X06066123


Add to CiteULike CiteULike   Add to Complore Complore   Add to Connotea Connotea   Add to Del.icio.us Del.icio.us   Add to Digg Digg   Add to Reddit Reddit   Add to Technorati Technorati   Add to Twitter Twitter    What's this?