Advanced Search

Journal Navigation

Journal Home

Subscriptions

Archive

Contact Us

Table of Contents

Click here to sign up for SAGE Journal Email Alerts today!

Sign In to gain access to subscriptions and/or personal tools.
Indoor and Built Environment
This Article
Right arrow Full Text (PDF)
Right arrow References
Right arrow Alert me when this article is cited
Right arrow Alert me if a correction is posted
Services
Right arrow Email this article to a friend
Right arrow Similar articles in this journal
Right arrow Similar articles in Web of Science
Right arrow Alert me to new issues of the journal
Right arrow Add to Saved Citations
Right arrow Download to citation manager
Right arrowRequest Permissions
Right arrow Request Reprints
Right arrow Add to My Marked Citations
Citing Articles
Right arrow Citing Articles via Google Scholar
Right arrow Citing Articles via Scopus
Google Scholar
Right arrow Articles by Kim, S.
Right arrow Articles by Moon, S.-J.
Right arrow Search for Related Content
Social Bookmarking
 Add to CiteULike   Add to Complore   Add to Connotea   Add to Del.icio.us   Add to Digg   Add to Reddit   Add to Technorati   Add to Twitter  
What's this?

Evaluation of VOC Emissions from Building Finishing Materials Using a Small Chamber and VOC Analyser

Sumin Kim

Laboratory of Adhesion and Bio-Composites, Program of Environmental Materials Science, Seoul National University, Seoul 151-921, South Korea

Hyun-Joong Kim

Laboratory of Adhesion and Bio-Composites, Program of Environmental Materials Science, Seoul National University, Seoul 151-921, South Korea, hjokim{at}snu.ac.kr

Suck-Joong Moon

R&D Department, Medical and Environmental Devices Division, ABILIT Corporation, Osaka 542-0081, Japan

A test chamber method was developed to provide a small and simple emission testing facility capable of testing construction products over a range of climatic parameters, such as temperature, ventilation rate and air velocity, that could be varied independently around typical indoor values. Volatile organic compounds (VOCs), specifically the aromatic hydrocarbons fraction, were measured using a "VOC analyser". This portable measuring equipment is a simple gas-chromatograph which is designed to measure certain aromatic compounds in indoor air. Compounds separated through the column are detected by a semiconductor gas sensor and the concentration of the target compounds automatically calculated and shown. Correlation of the results from this analyser with those from GC/MS was greater than 99%. We have examined the compounds emitted from various building materials, such as medium density fibreboard, particleboard (PB) and wood-based flooring (laminate flooring and engineered flooring), using test methods with a desiccator and 20L small chamber for analysis of VOCs and formaldehyde emission levels. Over 2 and 7 days, we tested the change of VOC emissions with time and compared the results for each material.

Key Words: VOC analyser • VOCs • 20L small chamber • building finishing materials

Indoor and Built Environment, Vol. 15, No. 6, 511-523 (2006)
DOI: 10.1177/1420326X06072040


Add to CiteULike CiteULike   Add to Complore Complore   Add to Connotea Connotea   Add to Del.icio.us Del.icio.us   Add to Digg Digg   Add to Reddit Reddit   Add to Technorati Technorati   Add to Twitter Twitter    What's this?