Indoor and Built Environment

 

Advanced Search

Journal Navigation

Journal Home

Subscriptions

Archive

Contact Us

Table of Contents

Register here to gain access to SAGE's 500+ Journals Online

Sign In to gain access to subscriptions and/or personal tools.
This Article
Right arrow Full Text (PDF)
Right arrow References
Right arrow Alert me when this article is cited
Right arrow Alert me if a correction is posted
Services
Right arrow Email this article to a friend
Right arrow Similar articles in this journal
Right arrow Similar articles in ISI Web of Science
Right arrow Alert me to new issues of the journal
Right arrow Add to Saved Citations
Right arrow Download to citation manager
Right arrowRequest Permissions
Right arrow Request Reprints
Right arrow Add to My Marked Citations
Citing Articles
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by Xu, X.
Right arrow Articles by Wang, S.
Right arrow Search for Related Content
Social Bookmarking
 Add to CiteULike   Add to Connotea   Add to Del.icio.us   Add to Digg   Add to Reddit   Add to Technorati  
What's this?
Indoor and Built Environment, Vol. 16, No. 5, 426-437 (2007)
DOI: 10.1177/1420326X07082744

An Adaptive Demand-Controlled Ventilation Strategy with Zone Temperature Reset for Multi-Zone Air-Conditioning Systems

Xinhua Xu

Department of Building Services Engineering, The Hong Kong Polytechnic University, Hung Hom Kowloon, Hong Kong, China

Shengwei Wang

Department of Building Services Engineering, The Hong Kong Polytechnic University, Hung Hom Kowloon, Hong Kong, China, beswwang{at}polyu.edu.hk

In air-conditioning systems serving multiple zones, conventional ventilation strategies often result in over-ventilation in some zones with under-ventilation in the other zones when the heating/cooling load and occupancy profiles of zones differ greatly. This article presents an adaptive demand-controlled ventilation (DCV) strategy for multi-zone air-conditioning systems, which employs real-time occupancy identification using the dynamic multi-zone ventilation equation and zone temperature set-point reset of critical zones. The strategy identifies the critical zones, and fully considers the outdoor air demand of critical zones and the unvitiated outdoor air in the re-circulated air from the other zones. The air temperature reset of critical zones results in the increase of their supply air fractions and therefore the amount of outdoor air delivered to the critical zones. Consequently the total outdoor airflow demand and the overall energy consumption are reduced while the ventilation of critical zones is satisfied. This adaptive DCV strategy is validated by comparing its energy and environmental performances with other typical ventilation strategies under various weather conditions.

Key Words: Demand-controlled ventilation • Multi-zone ventilation • Adaptive ventilation • Critical zone identification • Occupancy identification • Temperature resetting