Indoor and Built Environment

 

Advanced Search

Journal Navigation

Journal Home

Subscriptions

Archive

Contact Us

Table of Contents

Click here to register today!

Sign In to gain access to subscriptions and/or personal tools.
This Article
Right arrow Full Text (PDF)
Right arrow References
Right arrow Alert me when this article is cited
Right arrow Alert me if a correction is posted
Right arrow Citation Map
Services
Right arrow Email this article to a friend
Right arrow Similar articles in this journal
Right arrow Similar articles in ISI Web of Science
Right arrow Alert me to new issues of the journal
Right arrow Add to Saved Citations
Right arrow Download to citation manager
Right arrow Add to My Marked Citations
Google Scholar
Right arrow Articles by Zorman, T.
Right arrow Articles by Jersek, B.
Social Bookmarking
 Add to CiteULike   Add to Connotea   Add to Del.icio.us   Add to Digg   Add to Reddit   Add to Technorati  
What's this?
Indoor and Built Environment, Vol. 17, No. 2, 155-163 (2008)
DOI: 10.1177/1420326X08089251
© 2008 International Society of the Built Environment

Assessment of Bioaerosol Concentrations in Different Indoor Environments

Tina Zorman

Department of Food Science and Technology, Biotechnical Faculty, University of Ljubljana, Slovenia

Barbara Jersek

Department of Food Science and Technology, Biotechnical Faculty, University of Ljubljana, Slovenia, barbara.jersek{at}bf.uni-lj.si

The aim of this study was the assessment of bioaerosols in different indoor environments. The study was performed using volumetric culture plate air sampling to determine the concentration of viable bioaerosols. The results revealed that 60.9% of air samples from public places and all air samples collected in food processing plants had unacceptable levels of micro-organisms. This was based on a suggested standard which proposes that concentrations of viable micro-organisms should be no higher than 300 CFU · m-3. More detailed study of the bioaerosols collected showed that the main parameters of interest for indoor air quality were fungi and further characterization allowed identification of the genera present in a particular place. Acceptable indoor air quality, by the above standard, was found at a university faculty, in a fast food restaurant, a cultural centre, a health centre and a hospital, while it was not acceptable in meat-, mustard-, olive- and infant food-processing plants because the concentrations of moulds were higher than 150 CFU· m -3 and the predominant genus identified was Penicillium.

Key Words: Indoor air quality • bioaerosol • viable bacteria viable fungi • occupational hygiene


Add to CiteULike CiteULike   Add to Connotea Connotea   Add to Del.icio.us Del.icio.us   Add to Digg Digg   Add to Reddit Reddit   Add to Technorati Technorati    What's this?