Advanced Search

Journal Navigation

Journal Home

Subscriptions

Archive

Contact Us

Table of Contents

Click here to sign up for SAGE Journal Email Alerts today!

Sign In to gain access to subscriptions and/or personal tools.
Indoor and Built Environment
This Article
Right arrow Full Text (PDF)
Right arrow References
Right arrow Alert me when this article is cited
Right arrow Alert me if a correction is posted
Services
Right arrow Email this article to a friend
Right arrow Similar articles in this journal
Right arrow Similar articles in Web of Science
Right arrow Alert me to new issues of the journal
Right arrow Add to Saved Citations
Right arrow Download to citation manager
Right arrowRequest Permissions
Right arrow Request Reprints
Right arrow Add to My Marked Citations
Citing Articles
Right arrow Citing Articles via Google Scholar
Right arrow Citing Articles via Scopus
Google Scholar
Right arrow Articles by Hui, P.S.
Right arrow Articles by Mui, K.W.
Right arrow Search for Related Content
Social Bookmarking
 Add to CiteULike   Add to Complore   Add to Connotea   Add to Del.icio.us   Add to Digg   Add to Reddit   Add to Technorati   Add to Twitter  
What's this?

Using Carbon Dioxide Concentration to Assess Indoor Air Quality in Offices

P.S. Hui

Department of Building Services Engineering, The Hong Kong Polytechnic University

L.T. Wong

Department of Building Services Engineering, The Hong Kong Polytechnic University

K.W. Mui

Department of Building Services Engineering, The Hong Kong Polytechnic University, behorace{at}polyu.edu.hk

Carbon dioxide (CO2) concentration is commonly used as a surrogate indicator for assessing indoor air quality (IAQ) and ventilation efficiency. The measurement and analysis of average indoor CO2 concentration is useful to understand the performance of a ventilation system. However, uncertainties due to the ventilation rate effectiveness as well as the initial state, build-up, fluctuation, and decay of indoor CO2 concentration from occupant load variation have not been addressed in many measurements; considerable measurement efforts are obligatory. This study, taking the long-term CO2 measurement and occupant profile of a typical open-plan office building as reference, has developed a database to examine the probable errors of an alternative sampling scheme for assessing indoor CO2 level in which the average pollutant concentration is obtained from two short sampling periods in two sampling sessions when the building is occupied. The results show that the assessed CO2 level deviates from the long-term average and the probable errors correlate with the required measurement time and occupant load profile. At certain confidence levels, the potential reductions in measurement time of the alternative scheme, as compared with an 8-h continuous one, will be up to 30%, some 20% less than the reduction of measurement time for assessing indoor radon level.

Key Words: Offices • Indoor air quality (IAQ) • Carbon dioxide (CO2) sampling • Occupant load

Indoor and Built Environment, Vol. 17, No. 3, 213-219 (2008)
DOI: 10.1177/1420326X08091773