Advanced Search

Journal Navigation

Journal Home

Subscriptions

Archive

Contact Us

Table of Contents

Sign In to gain access to subscriptions and/or personal tools.
Indoor and Built Environment
This Article
Right arrow Full Text (PDF)
Right arrow Erratum for Solomon et al
Right arrow References
Right arrow Alert me when this article is cited
Right arrow Alert me if a correction is posted
Services
Right arrow Email this article to a friend
Right arrow Similar articles in this journal
Right arrow Alert me to new issues of the journal
Right arrow Add to Saved Citations
Right arrow Download to citation manager
Right arrowRequest Permissions
Right arrow Request Reprints
Right arrow Add to My Marked Citations
Citing Articles
Right arrow Citing Articles via Google Scholar
Right arrow Citing Articles via Scopus
Google Scholar
Right arrow Articles by Solomon, S.J.
Right arrow Articles by Burrows, J.P.
Right arrow Search for Related Content
Social Bookmarking
 Add to CiteULike   Add to Complore   Add to Connotea   Add to Del.icio.us   Add to Digg   Add to Reddit   Add to Technorati   Add to Twitter  
What's this?

VOC Concentrations in an Indoor Workplace Environment of a University Building

S.J. Solomon

Institute of Environmental Physics, University of Bremen, Germany, juliet{at}iup.physik.uni-bremen.de

G.W. Schade

Institute of Environmental Physics, University of Bremen, Germany, Department of Atmospheric Sciences, Texas A&M University, College Station, Texas, USA

J. Kuttippurath

Institute of Environmental Physics, University of Bremen, Germany, LMD/CNRS, Ecole Normale Supérieure, Paris Cedex 05, France

A. Ladstätter-Weissenmayer

Institute of Environmental Physics, University of Bremen, Germany

J.P. Burrows

Institute of Environmental Physics, University of Bremen, Germany

An indoor air quality survey was conducted at selected indoor environments in the Department of Physics and Electrical Engineering of the University of Bremen, Germany, during August 2005. The mean indoor/ outdoor (I/O) ratios of pollutants appeared to be higher than 1.0 for most volatile organic compounds (VOCs). Apart from direct emissions from indoor materials and infiltration of outdoor air, environmental tobacco smoke (ETS) was a dominant factor in indoor pollution. Pollutants which were commonly associated with cleaning products and materials, including monoterpenes, aldehydes and acetone exhibited general trends of higher concentrations indoors compared to outdoor levels. Indoor concentrations of many VOCs were found to be 2—10 times higher during weekdays as compared to the weekend, exhibiting a strong correlation with human activities. A comparison with previous studies on the health risks due to selected VOCs indicates that long-term exposure to the peak values reported in this study has potential to develop adverse health effects to the occupants whereby reducing the efficiency in the workplace.

Key Words: BTEX • Environmental tobacco smoke • Indoor air quality • Methanalyser • PTR-MS • VOC

Indoor and Built Environment, Vol. 17, No. 3, 260-268 (2008)
DOI: 10.1177/1420326X08090822