Indoor and Built Environment

 

Advanced Search

Journal Navigation

Journal Home

Subscriptions

Archive

Contact Us

Table of Contents

Sign In to gain access to subscriptions and/or personal tools.
This Article
Right arrow Full Text (PDF)
Right arrow References
Right arrow Alert me when this article is cited
Right arrow Alert me if a correction is posted
Services
Right arrow Email this article to a friend
Right arrow Similar articles in this journal
Right arrow Alert me to new issues of the journal
Right arrow Add to Saved Citations
Right arrow Download to citation manager
Right arrowRequest Permissions
Right arrow Request Reprints
Right arrow Add to My Marked Citations
Citing Articles
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by Yiu, J.
Right arrow Articles by Chan, M.Y.
Right arrow Search for Related Content
Social Bookmarking
 Add to CiteULike   Add to Connotea   Add to Del.icio.us   Add to Digg   Add to Reddit   Add to Technorati  
What's this?
Indoor and Built Environment, Vol. 4, No. 3-4, 227-236 (1995)
DOI: 10.1177/1420326X9500400312

IAQ in Large Enclosed Car-Parks in Hong Kong

Joanna Yiu

Department of Building Services Engineering, The Hong Kong Polytechnic University, Hong Kong

John Burnett

Department of Building Services Engineering, The Hong Kong Polytechnic University, Hong Kong

M.Y. Chan

Department of Building Services Engineering, The Hong Kong Polytechnic University, Hong Kong

With the increasing number of vehicles on Hong Kong's roads there is a heavy demand for car parking spaces, especially in commercial areas. Given the shortage of land for development in the territory, multi-storey and under ground car-parks seem to offer the best solution for Government and develop ers alike. However, provision of adequate mechanical ventilation is essential to maintain an acceptable air quality in enclosed and underground car-parks. The overall purpose of a study undertaken by the authors was to develop improved methods for designing car-park ventilation systems. This paper con siders current concerns in Hong Kong on the environment in car-parks, and reports on an ongoing survey of car-park environments, as determined by car bon monoxide concentrations, and on existing ventilation system design and operation. Current design guidelines and ventilation design methodologies used in Hong Kong are reviewed and their suitability for local application is examined. Typical design and operating problems found in car-parks are dis cussed. Case studies of typical underground car-parks in the territory are included.

Key Words: Car-park ventilation • Air quality standard • Vehicle emission • Ventilation design


Add to CiteULike CiteULike   Add to Connotea Connotea   Add to Del.icio.us Del.icio.us   Add to Digg Digg   Add to Reddit Reddit   Add to Technorati Technorati    What's this?