Indoor and Built Environment

 

Advanced Search

Journal Navigation

Journal Home

Subscriptions

Archive

Contact Us

Table of Contents

Register here to gain access to SAGE's 500+ Journals Online

Sign In to gain access to subscriptions and/or personal tools.
This Article
Right arrow Full Text (PDF)
Right arrow Alert me when this article is cited
Right arrow Alert me if a correction is posted
Services
Right arrow Email this article to a friend
Right arrow Similar articles in this journal
Right arrow Alert me to new issues of the journal
Right arrow Add to Saved Citations
Right arrow Download to citation manager
Right arrowRequest Permissions
Right arrow Request Reprints
Right arrow Add to My Marked Citations
Citing Articles
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by Chow, W.K.
Right arrow Articles by Wong, L.T.
Right arrow Search for Related Content
Social Bookmarking
 Add to CiteULike   Add to Connotea   Add to Del.icio.us   Add to Digg   Add to Reddit   Add to Technorati  
What's this?
Indoor and Built Environment, Vol. 5, No. 2, 82-98 (1996)
DOI: 10.1177/1420326X9600500204

Experimental Studies on the Air Flow Characteristics Induced by a High Sidewall Grill in a Climate Chamber

W.K. Chow

Department of Building Services Engineering, The Hong Kong Polytechnic University, Hong Kong

L.T. Wong

Department of Building Services Engineering, The Hong Kong Polytechnic University, Hong Kong

The air flow characteristics induced by discharging air into a climatechamber with and without a high sidewall grill were studied experimentally. Over five hundred and thirty thousand values of the air speed were collected at positions above the floor level, near the supply inlet and the exhaust outlet. The thermal comfort indices due to temperature and air speed were measured under five flow conditions, two with a diffuser and three without a diffuser. An evalua tion of thermal comfort using the air diffusion performance index (ADPI) and percentage dissatisfied (PD) was made. Macroscopic numbers describing the air flow studied were, the Archimedes number, the Reynolds number and the jet momentum number. The Reynolds number and the jet momentum num ber increased as the total supply flow rate increased. However, the Archimedes number decreased with increasing flow rates. The Archimedes number was found to be correlated with the Reynolds number, which might be because they are defined by parameters related to the air velocity V and temperature difference (T2 - T1). The ADPI was found to be linearly related to the jet momentum number and related directly to the PD. The throw of the diffuser was found to be related to the corrected Archimedes number. The jet momen tum number and Archimedes number are related to the air speed, the root mean square of the air speed and the turbulence intensity.

Key Words: Airflow • Sidewall grill • Archimedes number • Reynolds number • Climate chamber


Add to CiteULike CiteULike   Add to Connotea Connotea   Add to Del.icio.us Del.icio.us   Add to Digg Digg   Add to Reddit Reddit   Add to Technorati Technorati    What's this?