Indoor and Built Environment

 

Advanced Search

Journal Navigation

Journal Home

Subscriptions

Archive

Contact Us

Table of Contents

Register here to gain access to SAGE's 500+ Journals Online

Sign In to gain access to subscriptions and/or personal tools.
This Article
Right arrow Full Text (PDF)
Right arrow References
Right arrow Alert me when this article is cited
Right arrow Alert me if a correction is posted
Services
Right arrow Email this article to a friend
Right arrow Similar articles in this journal
Right arrow Alert me to new issues of the journal
Right arrow Add to Saved Citations
Right arrow Download to citation manager
Right arrowRequest Permissions
Right arrow Request Reprints
Right arrow Add to My Marked Citations
Citing Articles
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by Chan, M.Y.
Right arrow Articles by Chow, W.K.
Right arrow Search for Related Content
Social Bookmarking
 Add to CiteULike   Add to Connotea   Add to Del.icio.us   Add to Digg   Add to Reddit   Add to Technorati  
What's this?
Indoor and Built Environment, Vol. 6, No. 6, 350-357 (1997)
DOI: 10.1177/1420326X9700600606

Personal Exposure to Carbon Monoxide in Underground Car Parks in Hong Kong

M.Y. Chan

Department of Building Services Engineering, The Hong Kong Polytechnic University, Kowloon, Hong Kong

J. Burnett

Department of Building Services Engineering, The Hong Kong Polytechnic University, Kowloon, Hong Kong

W.K. Chow

Department of Building Services Engineering, The Hong Kong Polytechnic University, Kowloon, Hong Kong

An extensive survey has been carried out in 52 underground car parks in Hong Kong focusing on carbon monoxide concentrations in the air. So far as short- term health effects are concerned this compound is generally regarded as the most important chemical species from car exhausts. Its presence can be used to quantify air pollution, and give an indicator of the air quality in car parks. The sites were sampled during peak hours. This report presents the results and analysis of the carbon monoxide levels measured. Of the 52 sites surveyed, 27 were rated as 'good', 7 'acceptable' and 18 'poor' according to our interpreta tion of recommended international health criteria. The findings also revealed that the utilisation rate of car parks varied significantly over time.

Key Words: Car park • Carbon monoxide • Personal exposure • Exposure risk • Ventilation


Add to CiteULike CiteULike   Add to Connotea Connotea   Add to Del.icio.us Del.icio.us   Add to Digg Digg   Add to Reddit Reddit   Add to Technorati Technorati    What's this?