Advanced Search

Journal Navigation

Journal Home

Subscriptions

Archive

Contact Us

Table of Contents

Sign In to gain access to subscriptions and/or personal tools.
Indoor and Built Environment
This Article
Right arrow Full Text (PDF)
Right arrow References
Right arrow Alert me when this article is cited
Right arrow Alert me if a correction is posted
Services
Right arrow Email this article to a friend
Right arrow Similar articles in this journal
Right arrow Alert me to new issues of the journal
Right arrow Add to Saved Citations
Right arrow Download to citation manager
Right arrowRequest Permissions
Right arrow Request Reprints
Right arrow Add to My Marked Citations
Citing Articles
Right arrow Citing Articles via Google Scholar
Right arrow Citing Articles via Scopus
Google Scholar
Right arrow Articles by Vishnevsky, E.P.
Right arrow Search for Related Content
Social Bookmarking
 Add to CiteULike   Add to Complore   Add to Connotea   Add to Del.icio.us   Add to Digg   Add to Reddit   Add to Technorati   Add to Twitter  
What's this?

Economic Comparison of Two Energy-Efficient Design Strategies for Mechanical Ventilation Systems

E.P. Vishnevsky

Petrospek, Saint Petersburg, Russia

Two systems, one with air re-circulation alone and the other a combination of air re-circulation and energy recovery using plate heat exchangers have been ana lysed. For these systems, a set of equations was derived for partial or full re-circulation of air with and without plate heat exchangers. Also, as part of the analysis, the reciprocal ratio of investment and running costs was considered. In this analysis, the re-circulation factor pro vided by ventilation units, a bypass factor and the effi ciency of a plate heat exchanger were considered to be variables. For the sake of simplicity, the outdoor temper ature was assumed to change uniformly throughout the year from a winter time minimum to a summer time maximum. All the final mathematical expressions de rived are non-dimensional. The technical and economic estimations proposed were those which gave the most pessimistic outcome, that is, those for which the out come gave the lowest guaranteed common profit. The numerical calculations showed that quite different re sults were obtained depending on specific applications. Several economic indexes were estimated including payback times and capital and running costs for typical examples. The expected payback time for a system with plate heat exchanger is something like 2.0 years for an installation in the climate zone of Saint Petersburg, installed and run in accordance with Russian legislation.

Key Words: Heat exchangers • Design strategy • Energy saving

Indoor and Built Environment, Vol. 9, No. 2, 118-122 (2000)
DOI: 10.1177/1420326X0000900208


Add to CiteULike CiteULike   Add to Complore Complore   Add to Connotea Connotea   Add to Del.icio.us Del.icio.us   Add to Digg Digg   Add to Reddit Reddit   Add to Technorati Technorati   Add to Twitter Twitter    What's this?