Indoor and Built Environment

 

Advanced Search

Journal Navigation

Journal Home

Subscriptions

Archive

Contact Us

Table of Contents

Click here to register and gain free access

Sign In to gain access to subscriptions and/or personal tools.
This Article
Right arrow Abstract Freely available
Right arrow Free Full Text (Free PDF) Free
Right arrow Alert me when this article is cited
Right arrow Alert me if a correction is posted
Services
Right arrow Email this article to a friend
Right arrow Similar articles in this journal
Right arrow Similar articles in ISI Web of Science
Right arrow Alert me to new issues of the journal
Right arrow Add to Saved Citations
Right arrow Download to citation manager
Right arrowRequest Permissions
Right arrow Request Reprints
Right arrow Add to My Marked Citations
Citing Articles
Right arrow Citing Articles via ISI Web of Science (5)
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by Hui, P. S.
Right arrow Articles by Mui, K. W.
Right arrow Search for Related Content
Social Bookmarking
 Add to CiteULike   Add to Connotea   Add to Del.icio.us   Add to Digg   Add to Reddit   Add to Technorati  
What's this?
Indoor and Built Environment, Vol. 15, No. 4, 373-378 (2006)
DOI: 10.1177/1420326X06067866

Feasibility Study of an Express Assessment Protocol for the Indoor Air Quality of Air-conditioned Offices

P. S. Hui

Department of Building Services Engineering, The Hong Kong Polytechnic University, Hong Kong, China

L. T. Wong

Department of Building Services Engineering, The Hong Kong Polytechnic University, Hong Kong, China

K. W. Mui

Department of Building Services Engineering, The Hong Kong Polytechnic University, Hong Kong, China, behorace{at}polyu.edu.hk

It is costly to sample all major toxic pollutants in community air. Sampling should be conducted based on an assessment strategy and monitoring planning. Assessment methods that rely on monitoring some representative pollutants have been proposed variously at different times. In Hong Kong, the Environmental Protection Department (HKEPD) launched an Indoor Air Quality (IAQ) certification scheme to grade the IAQ in workplaces as "Excellent" or "Good" by measuring the levels of 12 indoor environmental parameters, i.e. carbon dioxide (CO2), carbon monoxide (CO), respirable suspended particulates (RSP), nitrogen dioxide (NO2), ozone (O3), formaldehyde (HCHO), total volatile organic compounds (TVOC), radon (Rn), airborne bacteria count (ABC), temperature (T), relative humidity (RH) and air velocity (V). The present study proposes an Express Assessment Protocol (EAP) to quantify IAQ problems by assessing the "dominant" contributors to unacceptable IAQ prior to any detailed assessment for benchmark purposes. To aid this, a comprehensive measurement of the 12 stated indoor environmental parameters was performed in some Hong Kong offices. The results were used to identify the dominant contributors and assess the performance of the proposed protocol in identifying the associated IAQ problems in an office environment. Comparing the results with the parameter measurements in the certification scheme they showed that for the "Excellent" IAQ level, 96% (94 to 98% for 95% confidence interval (CI)) of the "unacceptable" offices (414 samples) could be identified from the measurements of TVOC, RSP and HCHO; while those that achieved the "Good" level, 93% (90 to 97% for 95% CI) of them (201 samples) could be identified from the measurements of TVOC, ABC, RH, HCHO and O3. The EAP would be a useful tool for policymakers, building owners and professionals to quantify IAQ problems in offices and to make improved decisions based on resources and manpower management for efficient mitigation actions.

Key Words: IAQ • measurement • Express Assessment Protocol • Office • Air-conditioning

References

  • Cheong KW, Chong KY: Development and application of an indoor air quality audit to an air-conditioned building in Singapore : Building Environ 2001;36: 181-188 .
  • Cheong KW, Lau HY: Development and application of an indoor air quality audit to an air-conditioned tertiary institutional building in the tropics : Building Environ 2003;38: 605-616 .[CrossRef]
  • Chao Y, Chan Y, Ho L: Feasibility study of an Indoor Air Quality measurement protocol on 12 parameters in mechanically ventilated and air-conditioned buildings : Indoor Built Environ 2001;10: 3-19 .[CrossRef]
  • Lee SC, Guo H, Li WM, Chan LY: Inter-comparison of air pollutant concentrations in different indoor environments in Hong Kong : Atmos Environ 2002;36: 1929-1940 .[CrossRef]
  • Kraenzmer M: Modeling and continuous monitoring of indoor air pollutants for identification of sources and sinks : Environ Int 1999;25(5): 541-551 .[CrossRef]
  • Jokl MV: Evaluation of indoor air quality using the decibel concept based on carbon dioxide and TVOC : Building Environ 2000;35: 677-697 .[CrossRef]
  • Möhle G, Crump D, Brown V, Hunter C, Squire R, Mann H, Raw GJ: Development and application of a protocol for the assessment of indoor air quality : Indoor Built Environ 2003: June 12: 139-149 .
  • Hoskins JA: Health Effects Due to Indoor Air Pollution : Indoor Built Environ 2003;12: 427-433 .[CrossRef]
  • Seitz T: NIOSH indoor air quality investigations: 1971 through 1988 . Proceeding of Indoor Air Quality International Symposium, 1990; pp. 163-171 .
  • Melius J, Wallingford K, Keenlyside R, Carpenter J: Indoor air quality: The NIOSH experience : Ann Am Conf Governmental Indust Hygienists 1984;10: 3-7 .
  • US Environmental Protection Agency, National Institute for Occupational Safety and Health: Building Air Quality: A Guide for Building Owners and Facility Managers. Washington, USEPA 1991.
  • Crandall M, Sieber W: The National Institute for Occupational Safety and Health Indoor Environmental Evaluation Experience. 1. Building environmental evaluations : Appl Occup Environ Hyg 1996;11: 533-539 .
  • Malkin R, Wilcox T, Sicber W: The National Institute for Occupational Safety and Health Indoor Environmental Evaluation Experience. 2. Symptom prevalence : Appl Occup Environ Hyg 1996;11: 540-545 .
  • Sieber W, Stayner L, Malkin R, Petersen M, Mendell M, Wallingford K, Crandall M, Wilcox T, Reed L: The National Institute for Occupational Safety and Health Indoor Environmental Evaluation Experience. 3. Associations between environmental factors and self-reported health conditions : Appl Occup Environ Hyg 1996;11: 1387-1392 .
  • ENV Ministry of the Environment: Singapore guidelines for good indoor air quality in office premises. Singapore 1996.
  • HKEPD Indoor Air Quality Information Centre: Indoor air quality certification schemes for offices and public places. Hong Kong Environmental Protection Department. Government of the Hong Kong Special Administrative Region, China 2003.
  • Exposure Guidelines for Residential Indoor Air Quality: A Report of the Federal-Provincial Advisory Committee on Environmental and Occupational Health, Health Canada 1987.
  • Environment Australia: State of Knowledge Report: Air Toxics and Indoor Air Quality in Australia. Department of the Environment and Heritage, Australian Government 2001.
  • Institute of Environmental Epidemiology: Guidelines for Good Indoor Air Quality in Office Premises. Ministry of the Environment, Singapore 1996.
  • Air Quality Guidelines for Europe, 2nd edn. WHO, Copenhagen 2000.
  • Womble SE, Girman JR, Ronca EL, Axelrad R, Brightman HS, McCarthy JF: Developing Baseline Information on Buildings and Indoor Air Quality (BASE ’94): Part I - Study Design, Building Selection, and Building Descriptions : Healthy Buildings ’95 1995;3: 1305-1310 .
  • Burnett J: Indoor air quality certification scheme for Hong Kong buildings . Indoor Built Environ 2005;14: 201-208 .[CrossRef]
  • Mui KW, Wong LT, Hui PS: A new sampling approach for assessing indoor air quality : Indoor Built Environ 2006;15: 165-172 .[CrossRef]
  • Mui KW, Wong LT: Evaluation on sampling period for assessing indoor radon level with a long-term measurement of Hong Kong : Atmos Environ 2004; 38(39): 6711-6723 .[CrossRef]
  • Mui KW, Wong LT, Ho WL: Evaluation on sampling location for assessing indoor air quality : Building Environ 2006;41(11): 1515-1521 .[CrossRef]
  • Jones AP: Indoor air quality and health : Atmos Environ 1999;33: 4535-4564 .[CrossRef]
  • Chow WK, Wong LT: Experimental studies on air diffusion of a linear diffuser and associated thermal comfort indices in an air-conditioned space : Building Environ 1994;29(4): 523-530 .[CrossRef]
  • Chow WK, Wong LT: Survey on the air diffusion devices for air-conditioning systems in Hong Kong : Energy Engineering 1998;95(6): 50-79 .
  • Wong LT, Mui KW, Law KY, Hui PS: Epistemic assessment of radon levels of offices in Hong Kong : Atmos Environ 2006;40: 1441-1451 .[CrossRef]

Add to CiteULike CiteULike   Add to Connotea Connotea   Add to Del.icio.us Del.icio.us   Add to Digg Digg   Add to Reddit Reddit   Add to Technorati Technorati    What's this?



This Article
Right arrow Abstract Freely available
Right arrow Free Full Text (Free PDF) Free
Right arrow Alert me when this article is cited
Right arrow Alert me if a correction is posted
Services
Right arrow Email this article to a friend
Right arrow Similar articles in this journal
Right arrow Similar articles in ISI Web of Science
Right arrow Alert me to new issues of the journal
Right arrow Add to Saved Citations
Right arrow Download to citation manager
Right arrowRequest Permissions
Right arrow Request Reprints
Right arrow Add to My Marked Citations
Citing Articles
Right arrow Citing Articles via ISI Web of Science (5)
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by Hui, P. S.
Right arrow Articles by Mui, K. W.
Right arrow Search for Related Content
Social Bookmarking
 Add to CiteULike   Add to Connotea   Add to Del.icio.us   Add to Digg   Add to Reddit   Add to Technorati  
What's this?