Perception of Air Quality and the Thermal Environment in Offices
Vincenc Butala
University of Ljubljana, Faculty of Mechanical Engineering, A ker eva 6, SI-1000 Ljubljana, Slovenia, vincenc.butala{at}fs.uni-lj.si
Simon Muhi
University of Ljubljana, Faculty of Mechanical Engineering, A ker eva 6, SI-1000 Ljubljana, Slovenia
People's perception of the thermal environment and the quality of air in mechanically and naturally ventilated office environments is discussed. Interdisciplinary research of the indoor environment (technical and medical fields) was based on the simultaneous measurement of the thermal environment parameters, as well on as on surveying employees during their normal working activities. The survey sought to determine the health status and health problems of those surveyed in the 6 months prior to the study, as well as the current state of health and current subjective evaluation of the thermal environment and air quality. Deviations between the measured values evaluated by predicted mean vote (PMV) — predicted percent of dissatisfied (PPD) model (PMV—PDD) and the subjective evaluations of thermal environment of those surveyed were found. The subjectively stated reasons for the health problems of employees gave precedence to natural, as opposed to mechanical, ventilation, which is confirmed by the average absence from work for health reasons. An index of health was defined and analyzed for the people within a building. Significant correlations between indoor air parameters and the way people felt were found. Findings from the study indicate a significant role for the psychological factors and psychological state of the respondents when subjectively describing the indoor environment.
Key Words: Thermal environment Perceived air quality Health index Symptom prevalence Well-being Air conditioning Natural ventilation
References
- Fanger PO: Thermal comfort: Analysis and applications in environmental engineering, Danish Technical Press, Copenhagen, 1970.
- Iso: ISO 7730: Moderate thermal environments - Determination of the PMV and PPD indices and specification of the conditions for thermal comfort, Geneva: International Organization for Standardization, 1994.
- deDear R., Brager GS: Developing an adaptive model of thermal comfort and preference: ASHRAE Trans 1998;104:145—167.
- deDear R., Brager GS: The adaptive model of thermal comfort and energy conservation in the built environment: Intl J Biometeorology 2001;45: 100—108.[CrossRef]
- Feriadi H., Wong NH, Chandra S., Cheong KW: Adaptive behaviour and thermal comfort in Singapore's naturally ventilated housing: Building Res Inf 2003;31:1: 13—23.[CrossRef]
- Ashrae: ASHRAE Standard 62—1989: Ventilation for acceptable indoor air quality., Atlanta, GA, USA: ASHRAE, 1989.
- Cen: CR 1752: Ventilation for buildings. Design criteria for the indoor environment, Brussels: European Committee for Standardization, CEN/TC 156, 1998.
- Bluyssen PM, Fernandes Edo, Groes L., Clausen G., Fanger PO, Valbjorn O., Bernhard CA, Roulet CA: European Indoor air quality audit project in 56 office buildings: Indoor Air 1996;6: 221—238.[CrossRef][Web of Science]
- Butala V., Gri
ar P., Novak P.: Can we have both indoor air quality and energy conservation in old school buildings: Indoor Air 1996;2: 271—276. - Butala V., Muhi
S., Turk J., Molan M., Mandelc-Grom M., Arneri N.: Indoor Air Quality and Air Distribution in Occupied spaces - Final report (in Slovenian). Research project No. L2-0528—0782-01, Ljubljana: University of Ljubljana, Faculty of Mechanical Engineering, 2001. - Pei QQ, Zhou ZP, You XH: The investigation of indoor environment condition of office building in Guangzhou (questionnaire and test method): Indoor Air 2005;1: 468—471.
- Wargocki P., Wyon D., Sundell J., Clausen G., Fanger P.: The effects of outdoor air supply rate in an office on perceived air quality, sick building syndrome (SBS) symptoms and productivity: Indoor Air 2000;10: 222—236.[CrossRef][Web of Science][Medline]
[Order article via Infotrieve]
- Seppänen O., Fisk WJ: Relationship of SBSsymptoms and ventilation system type in office building: Indoor Air 2002;2: 437—442.
- Wargocki P., Sundel J., Bishof W., Brundrett G., Fanger PO, Gyntelberg F., Hanssen SO, Harrison P., Pickering A., Seppänen O., Wouters P.: Ventilation and health in non-industrial indoor environments: report from a European Multidisciplinary Scientific Consensus Meeting (EUROVEN): Indoor Air 2002;12: 113—128.[CrossRef][Web of Science][Medline]
[Order article via Infotrieve]
- Burge S., Hedge A., Wilson S., Bass J., Robertson A.: Sick building syndrome: a study of 4373 office workers: Ann Occup Hyg 1987;31: 493—504.[Abstract/Free Full Text]
- Skov P., Valbjorn O.: The sick building syndrome in the office environment: The Danish Town Hall study: Environ Intl 1987;13: 339—349.[CrossRef]
- Stenberg B., Eriksson N., Hoog J., Sundell J., Wall S.: The sick building syndrome (SBS) in office workers. A case-referent study of personal, psychosocial and building-related risk indicators: Intl J Epidemiol 1994;23: 1190—1197.[CrossRef]
- Akimenko V., Andersen I., Lebowitz M., Lindvall T.: The sick building syndrome: Indoor Air 1986;6: 87—97.
- Menzies D., Bourbeau J.: Current concepts: Building-related illnesses: New Eng J Med 1997;337: 1524—1531.[Free Full Text]
- Molan G., Molan M.: Presentation of a model for measurement of mental work load at the working place, F. Avallone, J. Arnold, K. de Witte (ed.), Feelings work in Europe. Edizioni Angelo Guerini e associati SpA. Quarderni di psicologia del lavoro, Vol. 5. Milano, 1997. pp. 253—259.
- Molan G., Molan M.: Expert Model for Prediction of Human Performance, Proc Intl Conf on TQM and human factors - towards successful integration. Vol. 2, Linköping, 1999. pp. 253—258.
- Who: Air quality guidelines for Europe, second edition, WHO Regional Publications, European Series, No. 91, Copenhagen: Regional Office for Europe, 2000.
- Fanger PO: Introduction of the olf and decipol units to quantify air pollution perceived by humans indoors and outdoors: Energy Build 1988;12: 1—6.[CrossRef]
- Linz H., Pinney S., Keller J., White M., Buncher C.: Cluster analysis Applied to Building-Related Illness: J Occup Environ Med 1998;40: 165—171.[CrossRef][Web of Science][Medline]
[Order article via Infotrieve]
- Butala V., Muhi
S., Molan M.: Diagnostic of IAQ problems in the central office of Slovenia Telecom: Healthy buildings 2000;1: 181—186. - Muhi
S., Butala V., Molan M.: The Influence of indoor environment parameters and expressed subjective evaluation on well-being and health of employees in air-conditioned offices, 7th Rehva World Congress: Clima 2000. Napoli, 2001. pp. 169—176.
Indoor and Built Environment, Vol. 16, No. 4,
302-310 (2007)
DOI: 10.1177/1420326X06079886

CiteULike Complore Connotea Del.icio.us Digg Reddit Technorati Twitter What's this?
|
|