Indoor and Built Environment

 

Advanced Search

Journal Navigation

Journal Home

Subscriptions

Archive

Contact Us

Table of Contents

Click here to register today!

Sign In to gain access to subscriptions and/or personal tools.
This Article
Right arrow Full Text (PDF)
Right arrow References
Right arrow Alert me when this article is cited
Right arrow Alert me if a correction is posted
Services
Right arrow Email this article to a friend
Right arrow Similar articles in this journal
Right arrow Similar articles in ISI Web of Science
Right arrow Alert me to new issues of the journal
Right arrow Add to Saved Citations
Right arrow Download to citation manager
Right arrow Add to My Marked Citations
Citing Articles
Right arrow Citing Articles via HighWire
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by Hui, P.S.
Right arrow Articles by Mui, K.W.
Right arrow Search for Related Content
Social Bookmarking
 Add to CiteULike   Add to Connotea   Add to Del.icio.us   Add to Digg   Add to Reddit   Add to Technorati  
What's this?
Indoor and Built Environment, Vol. 16, No. 2, 139-147 (2007)
DOI: 10.1177/1420326X07076503
© 2007 International Society of the Built Environment

An Epistemic Indoor Air Quality Assessment Protocol for Air-Conditioned Offices

P.S. Hui

Department of Building Services Engineering, The Hong Kong Polytechnic University, Hong Kong, People's Republic of China

L.T. Wong

Department of Building Services Engineering, The Hong Kong Polytechnic University, Hong Kong, People's Republic of China

K.W. Mui

Department of Building Services Engineering, The Hong Kong Polytechnic University, Hong Kong, People's Republic of China

Long-term measurement could be the best approach to determine the average pollutant concentration of an indoor environment for decisions on mitigation measures. This approach requires considerable measurement effort for accurate results and hence indoor air quality (IAQ) assessment methods that need less effort have been developed. This study proposes an epistemic approach for assessing an acceptable office IAQ against certain indoor air pollutant exposure limits. Together with the prior understanding of failure rates of IAQ determined from a number of extensive survey studies, a sample test result of pollutant levels and the uncertainties of different sampling schemes, the probability of satisfactory IAQ for an assessed air-conditioned office could be quantified. In particular, assessment of an acceptable IAQ for some air-conditioned offices in Hong Kong was demonstrated by taking CO2 as an example pollutant. Accuracy of the failure rates was improved by the application of sampling correction factors and Bayesian statistics. The probabilities of an acceptable office IAQ were evaluated against a CO2 level limit. This approach would be useful for IAQ assessment in some air-conditioned offices.

Key Words: IAQ • Epistemic assessment • CO2 measurements • Air-conditioned offices


Add to CiteULike CiteULike   Add to Connotea Connotea   Add to Del.icio.us Del.icio.us   Add to Digg Digg   Add to Reddit Reddit   Add to Technorati Technorati    What's this?


This article has been cited by other articles:


Home page
BUILDING SERV ENG RES TECHNOLHome page
K. Mui, L. Wong, and M. Yeung
Epistemic demand analysis for fresh water supply of Chinese restaurants
Building Service Engineering, May 1, 2008; 29(2): 183 - 189.
[Abstract] [PDF]